Chicago New Condo Bathroom Inspection | Bathroom Safety Issues

All bathroom outlets must be 20 amps rated and must include GFCI protection (there might be one GFCI receptacle and other outlets connected to it and protected). Your new condo bathroom receptacles must be installed on #12 AWG wire which you can’t see without removing of the receptacle or at least its cover, but this is beyond our basic / visual inspection.

Bathroom GFCI Receptacles and Electrical Components

Bathroom GFCI receptacle protection is required by the NEC (National Electrical Code), and of course by the common sense – why would you risk getting electrocuted if you can secure your safety by installing GFCI outlet.
Since some bathrooms are currently equipped with many electrical current hungry devices, power supply requirements had to be slightly adjusted. We used to have a bathroom sharing an electrical circuit with exterior outlets, the kitchen, and a garage – not anymore.
Of course, the minimum requirement listed below is not going to work if you add a steam shower, heated electric floor, hydro-spa heater, several light [...]