Login
Register
Return to CheckThisHouse.com
Q&A
Questions
Unanswered
Tags
Categories
Ask a Question
Welcome to Q&A for
Home Maintenance
Q&A section, where you can ask questions and get answers from me and other members of the community.
Spam, self-promotion, questions with abusive, inappropriate language, and irrelevant questions will be deleted.
All of the questions are moderated!
You'll be notified when your question is answered. Please reply with
Feedback
to share whether a solution worked or didn't work. Thank you!
Connect on
Google+
Find on
Google+ Local
All categories
Attic Area
(37)
Bathrooms
(15)
Carbon Monoxide Detectors
(4)
Car Garage
(25)
Closet Lighting
(1)
Condo Inspection
(3)
Crawlspace Inspection
(5)
Electrical
(21)
Environmental
(6)
Exterior Walls
(2)
Fall Maintenance
(0)
Grading and Drainage
(18)
Handrails and Guardrails
(0)
Heating and AC
(86)
Home Safety
(0)
House Chimney
(50)
House Energy Savings
(2)
House Foundation
(1)
House Roof
(4)
House Ventilation
(9)
Interior Walls
(13)
Kitchens
(2)
Laundry Area
(2)
Plumbing
(136)
Smoke Detectors
(4)
Spring Maintenance
(2)
Summer Maintenance
(0)
Winter Maintenance
(1)
WHAT IS THE CAPACITY FOR NATURAL GAS A 10 INCH ALUMINUM FLUE LINER 45 FEET LONG
0
votes
asked
in
House Chimney
by
rabree
(
140
points)
Tweet
1 Answer
0
votes
The answer will vary depending on the arrangment of the liner and number of bends. Assuming the liner is completely verticle though the ontario canada gas code book says 1 130 000 btu/h for a natural draft burner and 2 223 000 btu/h for an induced draft burner. theres also a minumum limit for such a large liner.
answered
by
damlamb
(
140
points)
Related questions
0
votes
1
answer
106
views
What is the New York State requirement for flue size on a gas water heater.
asked
in
Plumbing
by
deblamanna
(
120
points)
0
votes
1
answer
86
views
How far is too far for a gas water heater flue to join the main vent stack?
asked
in
House Ventilation
by
tmitch
(
120
points)
gas water heater
gas water heater ventilation
gas water heater duct work
0
votes
1
answer
40
views
Chimney flue sizing, 4 inch WH vent connected to a 7 inch chimey liner
asked
in
House Chimney
by
twlalande
(
120
points)
water heater venting
chimney liner
0
votes
1
answer
34
views
What kind of chimney would require a SS liner with a natural gas furnace
asked
in
Heating System
by
joe-b
(
120
points)
chimney flue
boiler venting
0
votes
1
answer
114
views
Is the 5 ” chimney liner sufficient for venting the furnace and the new water heater tank?
asked
in
House Chimney
by
admin
(
20,250
points)
water heater venting
furance venting
chimney liner
chimney flue diameter