Print This Post
Each one of them provides the same type of service / protection – it saves lives by limiting duration of an electrical shock.

GFCI receptacle is the most popular device and it has been in service since early 1970′s. It looks almost like a regular electrical outlet, with two small buttons located usually in the center. The buttons are marked “test” and “reset”, sometimes in 2 different colors, sometimes the same shade as the GFCI receptacle body.
By pressing the test button your are creating a situation in which GFCI should trip and disconnect the power to anything plugged into the receptacle.
Unfortunately, millions of GFCI outlets installed in our homes have a little safety glitch, if improperly wired, the device will trip but the power remains on… pretty scary for a safety device – GFCI outlet safety.
GFCI receptacle has two terminals on the back marked “LINE” connection (this is where the power supply from electrical panel should be connected), and two terminals marked “LOAD” where additional outlets might be attached. By accidentally switching line and load wires in those millions of receptacles, the “glitch” is activated.
The easiest way to test your GFCI receptacle line – load connection is to insert a 3-light receptacle tester into it or connect a lamp to the device and push “test” button (the lamp method does not test other wiring problems). If the button trips but your light fixture remains on, the wiring has been most likely reversed and GFCI receptacle provides no protection at all.
Newer GFCI receptacles have a feature called “Smart Lock” which prevents this from happening. You can easily recognize those devices by a small padlock sign in one of the corners of the face plate – any improper wiring blocks the test button. This isn’t something that you must have, but make sure that your GFCI receptacle without the “Smart Lock” sign has been properly wired.
One, extremely important feature of GFCI receptacles is that they can be used to replace 2-prong / ungrounded outlets. This provides protection from electrical shock for us, but still no ground for equipment. Newly installed GFCI receptacle and all outlets connected downstream from it (on the load side) must be marked as “GFCI protected” and “not grounded” – this is a code requirement.
Learn How to Install GFCI Receptacle
GFCI portable devices plug into a regular house outlet and provide protection to whatever is plugged into them. Some of them look like an extension cord with a thicker section containing protective device, other have a weatherproof enclosure with a build in GFCI receptacle, etc. You should be using them in all situation where GFCI outlet receptacle or GFCC circuit breaker protection is required, but not available.
GFCI circuit breakers act almost the same way as a GFCI receptacle. While GFCI receptacle disconnects hot and neutral conductors, breaker takes care of the hot only / the neutral remains closed.
GFCI circuit breakers are much more expensive than receptacles, but in some cases it might be cheaper or easier to replace just one breaker instead of changing several outlets.
GFCI circuit breaker has a test button, which should trip the breaker handle to the center position when depressed. In order to reset the breaker, you have to push the handle all the way to “off” position, and than back to “on”.
You’ve learned about GFCI types and testing, its time to find out GFCI residential locations currently required by the 2008 NEC (National Electrical Code)
Related posts:
richard stanley
1 month ago
Does anyone make a GFCI receptacle that can be used with aluminum wiring — Or must I use a pigtail connection and add an additional box to accommdate the larger GFCI receptacle ?
admin checkthishouse.com
1 month ago
It’s not about finding devices that can be used with small size aluminum wiring. It’s about your safety and code requirements – in 1975, the NEC prohibited the use of single conductor aluminum wiring smaller than #8 (smaller gauges are #10, #12…). Pigtailing and / or installation of CO/ALR switches and outlets is not considered acceptable by Consumer Product Safety Commission (CPCS). So, in order to correctly install this new GFCI outlet receptacle, the electrical wiring should be replaced with a copper one, or the existing aluminum wire circuit should be repaired with a COPALUM parallel splice connector.