Crawlspace GFCI, At or Below Grade Level


GFCI – (Ground Fault Circuit Interrupter)

Crawlspace GFCI protection for receptacles changed slightly in 2008 NEC (National Electrical Code). 2005 NEC exception that allowed single receptacles for not easily moved appliances to be excluded from GFCI requirement has been removed.

Because of the moisture, flooding, drainage problems , crawlspace GFCI protection absolutely makes sense in such application. The only device that homeowners would probably prefer without GFCI protection is a sump pump, which used to be a part of that 2005 exception.

If you’re concerned about your crawlspace flooding, the solution would be to install a battery operated sump pump backup (make sure the battery is elevated above the highest water level mark). It would also make sense (just like with the garage ceiling GFCI) to install regular outlet in the crawlspace and GFCI receptacle protecting it somewhere by the crawlspace entrance or other area with higher traffic so you can easily spot the problem.

Related posts:

  1. Unfinished Basement GFCI Receptacles Unfinished basement receptacles require GFCI protection as stated in the...
  2. Back-Up Sump Pump – it’s Always About Taking Chances It’s in a human’s nature to believe that bad things...
  3. House Exterior GFCI Receptacles The 2008 NEC did not change house exterior GFCI receptacles...
  4. Garage GFCI Receptacles and GFCI in Accessory Buildings GFCI – (Ground Fault Circuit Interrupter) Exceptions for the garage...
  5. GFCI Locations in Residential Buildings based on 2008 NEC From this post you can follow links to all GFCI...

Leave a Reply

Copyright © 2008-2010 · House Maintenance, Remodeling & Repairs · Chicago Web Hosting · All Rights Reserved