House Maintenance Safety Issues and Hazards

Print This Post Print This Post

Combustion Air for Fuel Burning Appliances


All types of fuel burning appliances in our homes require air to properly burn that fuel. It is called Combustion Air and it actually has three functions:

  1. It  is required to properly burn fuel
  2. To dilute exhaust gases that are being vented to exterior
  3. To vent and cool appliances

The most popular fuel used in our homes is of course natural gas. For every one cubic foot of gas, there are 10 cubic feet of air needed for clean burning in addition to dilution and ventilation air.

There are two products out of a perfectly balanced gas combustion – carbon dioxide and water vapor, which are perfectly safe. However, if we limit the amount of air for the combustion process, there might be a third bi-product, unfortunately a deadly one – Carbon Monoxide.

Example:

Imagine a gas water heater in a small closet, behind the solid door and without any openings in walls providing that necessary combustion air. After using all of the closet’s air for its combustion process, the air pressure in the closet will become lower than the one inside the water heater vent flue pipe.

The water heater closet will pretty much act now like a vacuum and the exhaust gases may be sucked back into the closet space instead of being discharged to the exterior. Since the oxygen starving combustion process is now producing that deadly Carbon Monoxide, it will eventually leak through the gaps around the closet door into the house…

The areas designated for fuel burning appliances are described as confined space and un-confined space.


The water heater closet from my example could be a confined space – an area with a closed, solid door, and walls / ceiling that create a barrier between the appliance and the rest of the house.

A confined space is a room that has less than 50 cubic ft of air volume for every 1000 BTU/hr of appliance input .

If the water heater has a 40 000 BTU/hr rating, the room would have to have over 2000 cubic feet of volume to provide enough air (without additional sources) for proper combustion process.

Un-confined space is a room that has more than 50 cubic ft of air volume for every 1000 BTU/hr of appliance input (BTU/hr input should be on the appliance label / information tag).

Assuming that our example water heater closet itself is a confined space, and it is located in a room being an un-confined space, we would require two openings in the closet door or wall. One opening should be located within 12” from the floor, and second within 12” from the ceiling of the enclosure.

Openings between confined space and unconfined space must have at least 100 sq. inch area each and provide at least 1sq. inch of a free airflow area per 1000 BTU/hr of the appliance input (1/4” min. or larger mesh screen if installed over the openings, metal grills and louvers provide 60%-75% of their net free area, wood louvers only 20%-25%).

With the 40000 BTU/hr water heater input, the combustion process would require only 40 sq. inches of an opening at top and bottom, but you still have to obey the minimum 100 sq. inches per each opening.

Combustion air opening sizes between confined space and un-confined space (inside of the house air)

Up to 100K BTU/hr – 100 square inch openings
125K BTU/hr – 125 square inch openings
150K BTU/hr – 150 square inch openings

More about combustion air coming soon.

Related posts:

  1. Chicago Condo Inspection & Combustion Air Requirements This part will cover Chicago condo inspection combustion air requirements...
  2. Solid (Wood/Coal) Fuel-Burning Stove Chimney Venting As with every fuel-burning appliance, proper venting is always critical,...
  3. Water Heater PVC Vent Pipe and Power Venting Water heater PVC vent pipe information below does not apply...
  4. Flood Damaged Household Appliances Are you scratching your head wondering if your flood damaged...
  5. Crawlspace Venting or Not, Still a Dilemma? A quick answer would be yes for the crawlspace venting...

Leave a Reply

Copyright © 2008-2010 · House Maintenance, Remodeling & Repairs · Chicago Web Hosting · All Rights Reserved