• If you can see this link so can 1000's of other eyeballs every single day; advertise on checkthishouse.com
  • Home
  • About Me
  • Disclaimer
  • Virtual Help
  • Partners
    • Home Related
    • For your Home
    • Construction / Remodeling
    • Real Estate
    • Home Inspections
    • Internet Marketing
    • Home and Garden
    • Heating and AC
  • Contact
  • Q&A How to Ask
  • Advertising

Home Maintenance, Remodeling and Repairs

Home maintenance advice, home repairs, remodeling projects for home owners, buyers, from your Illinois home inspector

  • Attic
  • Electric
    • Electrical System Issues
    • GFCI / AFCI
  • Environmental
  • Exterior
    • Free Shed Plan
    • Grading / Drainage
    • House Roof
  • Foundations
    • Crawlspace
  • Garage
    • Car Garage Issues
  • House Maintenance
    • Fall Maintenance
  • HVAC
    • Air Conditioning System
    • Chimney Problems
    • Heating System
    • House Ventilation
  • Inspections
    • Chicago Condo Inspection
    • Crawlspace Inspection
  • Interior
    • Bathrooms
    • House Components Issues
    • Kitchens
  • Plumbing
    • Gas Water Heater
    • Plumbing Problems
  • Recalls
  • Safety
    • Carbon Monoxide
    • Handrails and Guardrails
    • Smoke Detectors
www.checkthishouse.com
You are here: Home / HVAC / Heating System / Condo Furnace Above the Ceiling – The Unprofessional Way

Condo Furnace Above the Ceiling – The Unprofessional Way

  Written by Dariusz Rudnicki     Print This Post   Leave a Comment


Looking at some condo gas furnace installations in compartments or closets above the ceiling makes me laugh, cry, and scream at the same time. I can’t even imagine what the installer of the furnace was thinking … or if he was thinking at all.

In HVAC trade, just like in any other, there are some basic rules that anyone performing the job should follow. Not because somebody wrote them down, but because there’s a reason to follow them. Many of the rules are common sense. Some must be just taken for granted, but all should be followed if you (the installer) are being paid for it.
This short story is just another proof that Chicago’s new condos are rarely (if ever) inspected by the city building department inspectors.
Access to the furnace closet located above the bathroom ceiling

  • The access to the furnace closet, located directly above the bathroom ceiling, was quite comfortable and served as an air combustion supplying port – this is the good part and where it unfortunately ends.

Extremely limited access to the forced air furnace installed above the bathroom ceiling

  • The condo furnace had been suspended from the ceiling in a far corner of the closet space. It had been positioned in such way that any attempt of servicing it would require a person to levitate horizontally in approximately 16” of clearance between the furnace front panel and the chimney wall. It appears that furnace installation was performed before the bathroom ceiling drywall went up – set it and forget it…

Furnace vent pipe negatively sloped, requires minimum quarter of an inch per foot pitch

  • For the furnace to vent efficiently, its vent pipe must be pitched up at least ¼” per linear foot of an entire run – this one drops down a few inches before connecting to the chimney. Another basic requirement for the gas appliance vent pipe installation, and an important safety issue.

Chicago furnace gas supply line installation requires drip leg

  • The gas supply line at the furnace had been installed without the required drip leg (this is Chicago, and it might not be required in all jurisdictions), and the flexible CSST pipe was missing straps along its run.

Air conditioning drip pan requires separate condensate drain - some jurisdiction permit safety disconnect switch instead

  • Protective drip pan under the furnace and A/C coil had been plumbed together with the coil main condensate drain pipe – two separate lines are requires to provide drainage in case one of them fails.

Another option is to install a drip pan condensate overflow safety switch which disconnects power to the air conditioning system in case the drip pan condensate level approaches overflow (not everywhere approved as a replacement for the drip pan separate drain pipe).

Forced air furnace filter compartment

  • Furnace service door was missing.
  • No air filter installed.

It wouldn’t take much effort and time to make this condo furnace installation work from the beginning. It’s just pure stupidity and a waste of time to whoever did it and will ever have to service.

Is your gas furnace installed above the condo ceiling? Look up there, and imagine yourself crawling and performing any type of maintenance on it.

More from Home Maintenance

  • House Electrical Panel and the Most Common Mistakes you Make — Home Maintenance, Remodeling and Repairs
  • House Electrical Panel in the Bathroom and Clothes Closet
  • Chicago Condo Inspection Manual | Condo Safety Issues & More

Home Maintenance Recommends

  • Reducing the Blood Cholesterol Levels the natural way  (Web Chit-Chat)
Blog Margeting Related Posts Plugin For Home MaintenanceAsk Home Maintenance To Recommend Your Posts Blog Marketing Related Posts Plugin Counter

  • delicious Bookmark on Delicious
  • digg Digg this post
  • facebook Recommend on Facebook
  • linkedin Share on Linkedin
  • reddit share via Reddit
  • stumble Share with Stumblers
  • technorati Share on technorati
  • twitter Tweet about it
  • yahoo_buzz Buzz it up
  • rss Subscribe to the comments on this post
  • email Tell a friend
Filed Under: Heating System Tagged With: condo furnace above the ceiling the unprofessional way, diy furnace installation, do yourself furnace, furnace, furnace installation above ceiling, gas furnace installation, new condos, pipe installation, safety issue, vent pipe
About Dariusz Rudnicki

I'm a retired Illinois home inspector, founder and editor of checkthishouse.com, a blog which attracts around 2 thousand readers daily and is dedicated to answering the many questions of home owners and home buyers.
Connect with me on Google+

Comment / Ask me a Question Cancel reply

You must be logged in to post a comment.

Sponsored Ads

  • www.checkthishouse.com

***Go to Home Maintenance Q&A section***

Sponsored Ads

www.checkthishouse.com
.

Home Safety Maintenance

House Maintenance Advice - Vocal Smoke Detector

Smoke Detector Safety Tips – is Your Life Worth at Least $10.00?

Second floor laundry chute mounted on the floor surface with a 9' drop underneath

Laundry Chute Hazard – a Convenient Way to a … Disaster

kidde carbon monoxide

Carbon Monoxide – Toxic Gas Without Taste, Smell or Color

The clothes dryer plastic vent is forbiden, any type of dryer vent should be as short as possible

Clothes Dryer Vent | Why is Dryer Vent Cleaning so Important

Perfect size and one of perfect shapes for the stairs handrail

Stair Handrails and Guardrails Safety Issues

Closet light safety - exposed incandescent light bulb is not permitted, too close to storage, poses fire hazard

Closet Fire | Closet Light Fixture Fire Hazards

Garbage disposal electrical wiring performed with a lamp cord, exposed bare wires, missing connection box cover

Garbage Disposal Wiring | Kitchen Disposal Safety

telesteps-telescopic-combiladder-fully-open

Telescopic Ladders Review – Watch Your Fingers!

Kitchen stove safety - single piece stove anti-tip bracket

Kitchen Stove Safety Anti Tip Bracket

House safety maintenance - climbable balcony guardrails are not permitted - watch your children

Balcony Railing Safety Code | Balcony Guardrails Safe for Children

***Go to Home Maintenance Q&A section***

Like us on Facebook

Search CheckThisHouse.com

Helpful links

  • A UTC Fire & Security Company
  • CDC
  • Consumer Search
  • CPSC
  • Energy Star
  • EPA – Environmental Protection Agency
  • Federal Pacific Electrical Panels
  • Going Green Basics
  • HVI – Home Ventilation Institute
  • IEMA
  • Mesothelioma Center
  • Nicor Gas
  • Peoples & North Shore Gas
  • Permit Place
  • Underwriters Laboratories
  • USFA
  • Zinsco Sylvania Electrical Panels

Sponsored Ads

  • If you can see this link so can 1000's of other eyeballs every single day; advertise on checkthishouse.com

Home Maintenance Alexa Stats

Recommend

Recommend [HomeMaintenance]

Home & Garden Blogs
bloglog
Connect with me on Google+

Last 7-days Popular Posts

  • House Water Heater Vent Pipe, How To Do It Right 2439 view(s)
  • Chimney Flue and Furnace / Water Heater Venting 1458 view(s)
  • Getting Rid of Mold in Your Attic| Killing Mold in Attic 634 view(s)
  • Attic Black Mold and Why is it Growing in Your Attic 592 view(s)
  • Code Requirement for Bathroom Vent Location | Bathroom Exhaust 578 view(s)
  • Where to Install Smoke Alarm Detector | Proper Smoke Alarm Location 553 view(s)
  • Attic Ventilation | How Many Attic Vents Your Roof Needs 520 view(s)
  • Plumbing Vent Problems in Your House | Sewer and Drain 508 view(s)
  • Saddle Valve Installation 491 view(s)
  • Carbon Monoxide Detector Alarm Locations | Where to Install CO Detector 437 view(s)

Last searched terms

  • - lock logo
  • - rafter vents
  • - gfci outlet installation
  • - removing attic mold
  • - gas+water+tank+vent+chimney
  • - gap between tile tub
  • - framing under a toilet
  • - causes of mold in attic
  • - chimneys in home
  • - floor joist with moisture problems

Visitors Currently Online

  • 05 visitor(s) online
  • powered by WassUp

Search CheckThisHouse.com

Return to top of page

Copyright © 2012 · Home Maintenance · Chicago Web Hosting · All Rights Reserved

  • follow:follow:
  • Become my Facebook friend Become my Facebook friend
  • Connect with me Connect with me
  • RSS RSS
  • Tweet with me Tweet with me
  • Subscribe to my YouTube Channel Subscribe to my YouTube Channel